Energy efficiency was the key focus of the development of this recent compressor range. The high-output in-house made airend with slow rotational speed reduces significantly the energy costs. In addition to this, the innovative design of the fail safe shaft seal, integrated oil filter and oil regulation valve, ensures external hoses are reduced to a minimum to guarantee the highest levels of quality and reliability are achieved.

This range comprises of fixed speed and regulated speed (RS) models and is available with energy-saving integrated refrigerant dryer and high efficient heat recovery system

  • High reliability and high quality compressed air
  • Superior energy efficiency
  • High flexibility
  • Small footprint
  • Low maintenance costs

The modern design, made of quality components, provides the reliability operators expect from their compressed air source. The high-out airend and the energy efficient IE3 electric motor are the key constituents that guarantee highest performance levels. Being equipped with high performance separator filtration ensures highest quality air (< 3ppm oil carryover) is delivered to the compressed air network. The high efficient and extremely quiet thermostatically controlled motor driven fan allows compressor operation in the work place and the use of the maximum duct length without further assistance.

Delcos Pro Controller

The control system ensures reliable operation and protects the investment by continuously monitoring operational parameters. The Delcos Pro also has the capability to have programmable inputs and outputs, control additional equipment as well as providing the all relevant information in clear readable text:

  • Discharge/line pressure display
  • Air/oil temperature display
  • Total hours run and under load
  • Service due indicator
  • Enhanced fault log monitor
  • Real time clock
  • Timer controlled stop/start
  • Remote start/stop
  • Auto restart after power failure
  • Second pressure setting
  • Status indication
  • RS485 – Modbus RTU

The pressure setting can be easily adjusted via the controller.

CompAir L-Series L23 – L29 – Technical Data

L23 – L29 Fixed Speed

Compressor Model Nominal Pressure

[bar g]
Drive Motor

[kW]
FAD 1

[m3/min]
Noise Level 2

[dB(A)]
Weight

[kg]
Dimensions

L x W x H
[mm]
L23 7.5 22 4.16 67 650 1345 x 880 x 1612
10 22 3.45 67 650 1345 x 880 x 1612
13 22 2.98 67 650 1345 x 880 x 1612
L26 7.5 26 4.84 68 677 1345 x 880 x 1612
10 26 4.13 68 677 1345 x 880 x 1612
13 26 3.44 68 677 1345 x 880 x 1612
L29 7.5 30 5.52 69 681 1345 x 880 x 1612
10 30 4.81 69 681 1345 x 880 x 1612
13 30 4.12 69 681 1345 x 880 x 1612

L23F – L29F Fixed Speed with Integrated Dryer

Compressor Model Refrigeration dryer Pressure Dew Point 3

[°C]
Weight

[kg]
Dimensions

L x W x H
[mm]
L23F F29E 5 840 1675 x 880 x 1612
L26F F29E 5 867 1675 x 880 x 1612
L29F F29E 5 871 1675 x 880 x 1612

L23RS – L29RS Regulated Speed

Compressor Model Pressure

[bar g]
Drive Motor

[kW]
FAD1 at 7.5 bar g

[m3/min]
FAD1 at 10 bar g

[m3/min]
FAD1 at 13 bar g

[m3/min]
Noise level @ 70% load 2, 1m

[dB(A)]
Weight

[kg]
Dimensions

L x W x H
[mm]
Min Max
L23RS 5 13 22 1.11 – 4.12 1.03 – 3.50 1.35 – 2.89 68 681 1345 x 880 x 1612
L26RS 5 13 26 1.11 – 4.78 1.03 – 4.10 0.92 – 3.56 69 708 1345 x 880 x 1612
L29RS 5 13 30 1.11 – 5.41 1.03 – 4.50 0.92 – 3.82 69 712 1345 x 880 x 1612

L23RSF – L29RSF Regulated Speed with Integrated Dryer

Compressor Model Refrigeration dryer Pressure Dew Point3

[°C]
Weight

[kg]
Dimensions

L x W x H
[mm]
L23RSF F29E 5 871 1675 x 880 x 1612
L26RSF F29E 5 898 1675 x 880 x 1612
L29RSF F29E 5 902 1675 x 880 x 1612

1 Data measured and stated in accordance with ISO 1217 Edition 4, Annex C & E at the following conditions:
Air Intake Pressure 1 bar A / 14.5 psi, Air Intake Temperature 20°C / 68°F, Humidity 0% (dry)

2 Measured in free field conditions in accordance with ISO 2151, tolerance ± 3dB(A)

3 The refrigerant dryer requires a separate electric supply. Data refers to DIN ISO 7183, 8573-1:2001
(class 4, pressure dew point 3°C). For further specifications please refer to refrigerant dryer documentation.