The design concept is based on absolute reliability and flexibility. This range incorporates the latest technological advances and components which are designed for long service life to offer operators total piece of mind. The availability of a wide range of different version and options makes them suitable for almost all applications. This ranges from additional regulated speed models, receiver mounted versions including refrigerant dryer (Airstation) and integrated heat recovery option
The advanced design of the high efficiency airend allows operation at low rotational speeds, and consequently lowers the energy costs. The innovative integrated design, including oil separation, oil filter and thermostatic bypass valve, reduces the number of external hoses and components offering excellent reliability. The compressors are equipped with an energy saving IE 3 electric motor with reduced CO2emissions. As the compressors offer low noise levels they can be placed at the point of use.
Delcos Pro Controller
The control system ensures reliable operation and protects the investment by continuously monitoring operational parameters. The Delcos Pro also has the capability to have programmable inputs and outputs, control additional equipment as well as providing the all relevant information in clear readable text:
- Discharge/line pressure display
- Air/oil temperature display
- Total hours run and under load
- Service due indicator
- Enhanced fault log monitor
- Real time clock
- Timer controlled stop/start
- Remote start/stop
- Auto restart after power failure
- Second pressure setting
- Status indication
- RS485 – Modbus RTU
The pressure setting can be easily adjusted via the controller.
CompAir L-Series L07 – L22 – Technical Data
L07 – L22 Fixed Speed
Compressor Model | Nominal Pressure
[bar g]
|
Drive Motor
[kW]
|
FAD 1
[m3/min]
|
Noise Level 2
[dB(A)]
|
Weight
[kg]
|
Dimensions
L x W x H
[mm]
|
---|---|---|---|---|---|---|
L07 | 7.5 | 7.5 | 1.30 | 70 | 205 | 667 x 630 x 1050 |
10 | 1.06 | |||||
13 | 0.85 | |||||
L11 | 7.5 | 11 | 1.82 | 70 | 219 | 667 x 630 x 1050 |
10 | 1.61 | |||||
13 | 1.32 | |||||
L15 | 7.5 | 15 | 2.70 | 70 | 335 | 787 x 698 x 1202 |
10 | 2.26 | |||||
13 | 1.80 | |||||
L18 | 7.5 | 18.5 | 3.25 | 71 | 361 | 787 x 698 x 1202 |
10 | 2.74 | |||||
13 | 2.34 | |||||
L22 | 7.5 | 22 | 3.65 | 71 | 367 | 787 x 698 x 1202 |
10 | 3.21 | |||||
13 | 2.61 |
L07RS – L22RS Regulated Speed
Compressor Model | Nominal Pressure
[bar g]
|
Drive Motor
[kW]
|
FAD 1 | Noise Level at 70% load 2
[db(A)]
|
Weight
[kg]
|
Dimensions
L x W x H
[mm]
|
|
---|---|---|---|---|---|---|---|
min. | max. | ||||||
L07RS | 7.5 | 7.5 | 0.48 | 1.26 | 63 | 222 | 667 x 630 x 1050 |
10 | 0.44 | 1.01 | |||||
13 | 0.41 | 0.83 | |||||
L11RS | 7.5 | 11 | 0.63 | 1.81 | 64 | 231 | 667 x 630 x 1050 |
10 | 0.64 | 1.56 | |||||
13 | 0.57 | 1.26 | |||||
L15RS | 7.5 | 15 | 0.92 | 2.60 | 67 | 365 | 787 x 698 x 1202 |
10 | 0.86 | 2.18 | |||||
13 | 0.83 | 1.67 | |||||
L18RS | 7.5 | 18.5 | 1.33 | 3.05 | 68 | 381 | 787 x 698 x 1202 |
10 | 1.28 | 2.62 | |||||
13 | 1.22 | 2.20 | |||||
L22RS | 7.5 | 22 | 1.04 | 3.54 | 69 | 386 | 787 x 698 x 1202 |
10 | 0.93 | 3.15 | |||||
13 | 0.90 | 2.66 |
L07 – L22 / L07RS – L22RS Airstation
Compressor Model | Nominal Pressure
[bar g]
|
Refrigeration Dryer 3 | Air Receiver | Air Outlet | Weight
[kg]
|
Dimensions
L x W x H
[mm]
|
---|---|---|---|---|---|---|
L07 / L07RS | 7.5 | F12HS-BO | 270 litres | RP 3/4″ | 336 / 353 | 1541 x 695 x 1577 |
10 | ||||||
L11 / L11RS | 7.5 | F18HS-BO | 270 litres | RP 3/4″ | 350 / 362 | 1541 x 695 x 1577 |
10 | ||||||
L15 / L15RS | 7.5 | F30HS-BO | 500 litres | RP 1″ | 545 / 575 | 1883 x 815 x 1825 |
10 | ||||||
L18 / L18RS | 7.5 | F39HS-BO | 500 litres | RP 1″ | 617 / 637 | 1883 x 815 x 1825 |
10 | ||||||
L22 / L22RS | 7.5 | F39HS-BO | 500 litres | RP 1″ | 622 / 641 | 1883 x 815 x 1825 |
10 |
1 Data measured and stated in accordance with ISO 1217 Edition 4, Annex C & E at the following conditions:
Air Intake Pressure 1 bar A / 14.5 psi, Air Intake Temperature 20°C / 68°F, Humidity 0% (dry)
2 Measured in free field conditions in accordance with ISO 2151, tolerance ± 3dB(A)
3 The refrigerant dryer requires a separate electric supply. Data refers to DIN ISO 7183, 8573-1:2001
(class 4, pressure dew point 3°C). For further specifications please refer to refrigerant dryer documentation.