cng-booster-v-5740

Description

A higher volumetric efficiency and alignment of the cylinders directly in the cooling-air flow are the pre-conditions for low condensation temperatures and therefor long service life of the valves. The generously dimensioned industrial components guarantee long inspection intervals and low maintenance costs. A special system for leakage testing of the whole machine during standstill (without running noises) simplifies the diagnosis during maintenance work.

Booster:

  • Pressure switches for pressure stages and crankcase
  • High efficient cooling
  • Maintenance-free oil- and water-seperator
  • Microfilter at outlet
  • Ex motor, direct flanged
  • Elastic coupling for smooth start
  • Manometers for all stages and oil pressure
  • Oil-pressure-lubrication with oil-pressure-contorl and manometer
  • Full automatic discharge
  • Vibration-free three-point-assembly
  • Electromagentic start discharge

 

 

Technical data

Application, medium Erdgas
Max. operating pressure 300 bar
Stages 4
Druckvorstufen 1
Inlet pressure 30 / 35 / 40 bar
Delivery quantity 2267 / 2683 / 3150 l/min
Driving power 27 kW
Drive speed 1000 rpm
Cylinder count 4
Operating temperature 5 – 40 °C
Length 1640 mm
Width 1025 mm
Height 1120 mm
Weight 790 kg
Outlet temperature ca. 10 °C über Eingangstemperatur